| Frequency • High Band: 100 kHz-1 MHz
 • Low Band: 10 kHz-50 kHz
 • Optional Very Low Band 3
 kHz to 24 kHz
 Output Power
 • High: 100 kHz – 1 kW RMS max
 200 kHz – 900 W RMS max, 750
 kHz – 300 W RMS max
 • Low: 12 kHz – 2kW RMS max, 50
 kHz – 1.5kW RMS max
 • Very Low: 3kHz – 4kW (transducer
 impedance dependant)
 Input Power
 • 110 or 220 V AC or 24 VDC 50
 watts
 Resolution
 • 0.01m / 0.1 ft.
 Accuracy
 • 0.01m / 0.10 ft. +/- 0.1% of depth @
 200 kHz
 • 0.10m / 0.30 ft. +/- 0.1% of depth @
 33 kHz
 • 0.18m / 0.60 ft. +/- 0.1% of depth
 @12 kHz
 Depth Range
 • 0.2 – 200m / 0.5 – 600 ft. @ 200
 kHz
 • 0.5 – 1500m / 1.5 – 4500 ft. @ 33
 kHz
 • 1.0– 6000m / 3.0 – 20,000 ft. @ 12
 kHz
 Chart Scales
 • 5,10,20,40,80,100,200,400,800,
 1600 m
 • 15,30,60,120,240,300,600,1200,
 2400,4800 ft.
 Phasing
 • Automatic scale change, 10%,20%,
 30% overlap or Manual
 Printer
 • High resolution 8 dots/mm (203
 dpi), 16 gray shades
 • 216mm (8.5”) wide thermal paper or
 film
 • External ON/OFF switch
 • Paper advance control
 | Paper Speed • 1cm/min. (0.5”/min.) to 22 cm/mm
 (8.5”/min.)
 LCD Display
 • 15 inch TFT Screen
 • Sunlight Readable
 • Internal Data Storage in XTF format
 on 40GB Hard Disk
 • Data Transfer via Ethernet interface
 or USB Flash Drive
 Sound Velocity
 • 1370 – 1700 m/s
 • Resolution 1 m/s
 Transducer Draft Setting
 • 0 – 15m (0 – 50 ft.)
 Depth Display
 • On control PC and LCD display
 Clock
 • Internal battery backed time,
 elapsed time, and date clock
 Annotation
 • Internal – date, time, GPS position
 • External – from RS232 port
 Interfaces
 • 4 x RS232 and 1 x RS422 serial
 ports, baud rate selectable 4800-
 19200.
 • Inputs from external computer,
 motion sensor, sound velocity.
 • Outputs to external computer,
 remote display
 • Outputs with LCD chart – VGA
 video out
 • Ethernet interface
 • Heave – TSS1 and sounder
 sentence
 Blanking
 • 0 to full scale
 Installation
 • Desktop or optional rack mount and
 bulkhead
 Software
 • Echotrac Control supplied
 • ChartView supplied with LCD
 configuration
 Help
 The function of each parameter and it’s
 | minimum and maximum values can be printed on the paper chart. Also, a
 record of all parameter settings can be
 printed on the chart.
 Environmental Operating Conditions
 • 0°– 50° C, 5 – 90% relative
 humidity, Non-condensing
 Dimensions
 • 9mm (3.5”) H x 432mm (17”) W x
 432mm (17”) D
 Weight
 • 15.9 kg (35 lbs.)
 Options
 • Third Acoustic Channel (multiple
 configurations)
 • Remote Display
 • Side Scan Transducer – single or
 dual channel side looking 200 kHz
 for 340kHz for search and
 reconnaissance
 • Built-in DGPS
 |